Sunshine Lighting's first three quarters of revenue increased by 12% LED new business is expected to become a future growth point

LED industry as an emerging industry of energy conservation and environmental protection, led lighting recently issued by the State Council, "12th Five-Year" energy-saving emission reduction comprehensive work program has received policy attention.

The program clearly pointed out that it is necessary to speed up energy-saving renovation of facilities, strictly manage energy consumption, guide consumer behavior, and promote the use of high-efficiency energy-saving home appliances and lighting products among residents. And the "semiconductor lighting" was included in the "enhanced energy-saving emission reduction technology industrialization demonstration" project.

Sunshine Lighting released three quarterly reports, the company achieved operating income of 1.89 billion yuan in the first three quarters (the same below), an increase of 11.59%; net profit attributable to shareholders of listed companies was 179 million yuan, an increase of 0.16%; basic earnings per share was 0.286 yuan. Among them, Sunshine Lighting achieved revenue of 695 million yuan in the third quarter, up 13.11% year-on-year and 10% quarter-on-quarter; net profit was 91.096 million yuan, down 14.45% year-on-year and 202.4% quarter-on-quarter; the first quarter quarterly EPS were: 0.09, 0.05, 0.14.

Sunshine Lighting achieved operating income of 1.89 billion yuan in the first three quarters, an increase of 11.59% year-on-year; net profit reached 179 million yuan, an increase of 0.16% year-on-year, and the growth rate slowed down. The industry expects that with the gradual expansion of new LED business, the company's profitability will be effectively improved.

The structural adjustment of Sunlight's lighting products was effective, and the gross profit margin increased by 2.54 percentage points year-on-year. In the first three quarters, the company's gross profit margin was 19.78%, an increase of 2.54 percentage points year-on-year. The continued increase in gross profit margin was mainly attributable to the company's continuous product mix adjustment and increased revenue from new products with high gross profit.

The additional projects will expand production capacity and accelerate the pace of entering new areas. The company raised 917 million yuan through non-public issuance, all of which were used to invest in micro-mercury environmental protection and energy-saving lamp industrialization projects and Xiamen LED energy-saving lighting products. At present, the project is progressing smoothly. The company will speed up the construction of LED projects, increase the proportion of LED lighting products, and accelerate the transition to the overall lighting solution provider. With the gradual release of subsequent production capacity, LED business will become the company's new performance growth point.

Weak cables refer to cables used for security communications, electrical equipment, and related weak current transmission applications.

Wire and cable refers to materials used for power, communications, and related transmission purposes. "Wire" and "cable" do not have strict boundaries. Usually, the product with a small number of cores, a small product diameter, and a simple structure is called a wire. A wire without insulation is called a bare wire. Others are called cables. A conductor with a larger cross-sectional area (greater than 6 mm2) is called a large wire. Small (less than or equal to 6 mm2) is called a small wire, and an insulated wire is also called a cloth wire.

Wire and cable include bare wires, electromagnetic wires and insulated wires for electrical appliances, power cables, communication cables and optical cables.


Naming principle

1, the content included in the product name

(1) Product application or size class name

(2) product structure materials or types;

(3) Important or additional features of the product

Basically named in the above order, sometimes to highlight important or additional features, features are written before or before the corresponding structure description.

2, the order of the structure description

The product structure is described in terms of the principle from the inside to the outside: Conductor-->insulation-->inner sheath-->outer sheath.

3, simplified

Some structures describe writing or abbreviations without causing confusion.
Composition

From the inside to outside by the inner conductor, insulation, outer conductor and sheath;

Inner conductor: Since the attenuation is mainly caused by the resistance of the inner conductor, the inner conductor has a great influence on the signal transmission

Insulation: Impact attenuation, resistance, return loss and other properties

Outer conductor: loop conductor, shielding effect
Video signal transmission generally adopts direct modulation technology and takes the form of baseband frequency (about 8MHz bandwidth). The most common transmission medium is Coaxial Cable; coaxial cable is specially designed to transmit video signals, and its frequency loss, image distortion, The amplitude of image attenuation is relatively small, which can well complete the task of transmitting video signals.

Commonly used special SYV75 ohm series coaxial cable; commonly used model is SYV75-5 (its non-relay transmission distance for the video signal is generally 300-500m); when the distance is long, SYV75-7, SYV75-9 must be used Axle cable (In actual engineering, the relayless transmission distance of the thick cable can reach 1km or more)

The communication cable is generally used in an imaging device equipped with an electric pan/tilt head and an electric lens, and a remote control decoder must be installed in the field when in use; a communication transmission cable between the on-site decoder and the video matrix switching host of the control center is generally adopted. 2-core shielded communication cable (RVVP) or category 3 twisted pair UTP, with a cross-sectional area per core of 0.3mm² ~0.5mm²; the basic principle for selecting a communication cable is that the longer the distance, the larger the wire diameter; RS-485 communication regulations The basic communication distance is 1200m, but in the actual project, the RVV2-1.5 sheath line can be used to extend the communication length to over 2000m.

The control cable usually refers to the multi-core cable used to control the PTZ and the electric variable lens; one end of the control cable is connected to the PTZ of the controller or the decoder, and the electric lens controls the terminal, and the other end is directly connected to the PTZ. On the corresponding terminals of the electric lens, the control cable provides DC or AC voltage, and the distance is generally short (sometimes less than 1m). There is basically no interference problem, so no Shielded Cable is required.

Commonly used control cables mostly use 6-core or 10-core cables, such as RVV6-0.2, RVV10-0.12; 6-core cables are connected to the top, bottom, left, right, automatic, and public 6 terminals of PTZ respectively, 10 cores In addition to the six terminals of the pan-tilt head, the cable includes four zooming, focusing, aperture, and common terminals of the electric lens; in the monitoring system, the control cable from the decoder to the pan/tilt head and the lens is short due to the short distance. Generally do not make special requirements; and from the central control room controller to the pan and tilt and electric lens distance is as small as tens of meters, as many as several hundred meters, the control cable needs to have certain requirements, that is, the diameter of the wire should be thick, such as selection RVV10-0.5, RVV10-0.75

Audio Monitoring Cable generally uses 4-core shielded communication cable (RVVP) or Category 3 twisted pair UTP, with a cross-sectional area of 0.5 mm&sup2 per core;

The audio signal of the monitor head in the monitoring system is transmitted to the central control room and is a point-to-point wiring method. It is transmitted with high voltage and low current, so an unshielded 2-core cable can be used, such as RVV2-0.5.

RVV2*0.3 (signal line) and RVV4*0.3 (2-core + 2-core power) cables are generally used between the front-end detector and the alarm controller; the two controllers are generally used between the alarm controller and the terminal security center. Signal line

Whether the signal line is shielded or twisted or it is a common sheathed cable, it needs to be determined according to the requirements of various brands of products; the rough specification of the signal line diameter is determined according to the distance and quality of the alarm controller and the center; alarm control The power supply of the device generally uses local power instead of centralized power supply in the control room. The line is short, generally adopting RVV 2×0.5" or above specifications; the perimeter alarm and other public area alarm devices generally use centralized power supply mode, and the line is longer. RVV2*1.0" or above specifications are generally used

Cables used in building intercom systems are mostly cables such as RVV, RVVP, SYV, etc.

Has: transmission of voice, data, video images, while cable requirements also reflected in the quality of voice transmission, data transmission rate, video image transmission quality and speed, etc.

Cables that transmit voice signals and alarm signals mainly use RVV4-8*1.0

Video transmission is based on SYV75-5 cable

Some systems must use RVVP cables in the system when they are afraid of external interference or cannot be grounded.

Direct Push-to-Talk Visual Intercom System Line Standard:

Video terminals, two-way audio and remote control unlocking terminals of all indoor units are connected to the door machine in a bus way, but each call line is directly connected to the door machine alone.

--Video coaxial cable SYV75-5, SYV75-3

- Use a 4-core non-shielded or shielded sheath cable (AVVR4, RVV4, or RVVP4, etc.) for the microphone/speaker/unlock cord

- A 2-core jacket wire (AVVR2, RVV2, etc.) for the power cord

-- 2-wire shielded cable for call lines (RVVP2)

Digital coded push-button video intercom system:

- The main line includes video coaxial cable (SYV75-5, SYV75-3, etc.)

- Power cord (AVVR2, RVV2, etc.)

-- Audio/data control lines (RVVP4, etc.)

- Household Signal Line (RVVP6, etc.)

Low Current Cables

Low Current Cables,Charter Cable,Spectrum Cable,Coaxial Cable

Jiangsu QiSheng Cable Co., Ltd. , https://www.shuaihe-cable.com